The brakes of the home wheelchair lift should be checked regularly, and the gap between the brake pads and the brake wheels should be adjusted to ensure flexibility and reliability. There should be no dirt on the friction surface. If there is dirt, it must be rinsed with gasoline or diluted material. Pay attention to the broken wire and slack of each wire rope. Exceeding the specification must be replaced immediately. The maintenance of the wire rope should be carried out in strict accordance with the provisions of GB5144-85. Regularly check whether the mechanism is functioning properly and whether there is any noise. If a fault is found, it must be eliminated in time.
The lubrication of the gear boxes, external gears and other parts of the family wheelchair lift and the hydraulic oil shall be carried out according to the requirements of the lubrication table. Regularly check the connections of various departments, and tighten them if they are loose. When the body is compressed, it should be checked whether the body connecting bolts are tightened (the compression state can be caused by the method of rotating the arm). All lightly connected shafts must have cotter pins and be fully open.
When installing, disassembling and adjusting the slewing mechanism of the family wheelchair lift, care should be taken to ensure that the center line of the slewing mechanism reducer is parallel to the center line of the gear, the meshing surface is not less than 70%, and the meshing clearance should be appropriate. When the motor is overheated, it should be stopped in time and continue to run after troubleshooting. Motor bearings should be well lubricated. The control box, distribution box, etc. should be kept clean regularly, and the dust on the electrical equipment should be cleaned in time. Periodically inspect all wires and cables for damage. Damaged parts should be repaired and replaced in time. The contact surface of each part of the brush should be kept clean, and the pressure of the brush should be adjusted so that the contact area is not less than 50%.